Language: Chinese ∷  English
   Home   |   Heat Transfer Lab Equipments

Heat Transfer Lab Equipments

  • MR-WL 315C Trainer For Various Heat Exchangers
  • MR-WL 315C Trainer For Various Heat Exchangers
MR-WL 315C Trainer For Various Heat ExchangersMR-WL 315C Trainer For Various Heat Exchangers

MR-WL 315C Trainer For Various Heat Exchangers

  • Trainer For Various Heat Exchangers
  • Vocational Training Equipment
  • Teaching Equipment
  • Thermal Transfer Training Equipment
  • Product description: MR-WL 315C Trainer For Various Heat Exchangers Vocational Training Equipment Teaching Equipment Thermal Transfer Training Equipment
  • INQUIRY

MR-WL 315C Trainer For Various Heat Exchangers Vocational Training Equipment Teaching Equipment Thermal Transfer Training Equipment

examination and comparison of various heat exchanger types
five different types of heat exchangers included in the scope of delivery
finned heat exchanger with fan
operating mode (parallel flow or counter flow) selectable via valves
flow rates adjustable via valves
electromagnetic flow meter
digital displays for temperature, pressure differences and flow rate
Control Interface Box and Data Acquisition Board part of SCADA system

Technical Data Base service unit:
Stainless steel tank (30 l), equipped with:
Electric heating element (3000 W) with thermostat (70 °C), to heat the water, computer controlled.
Temperature sensor (“J” type) to measure the water temperature.
Level switch to control the water level in the tank.
Stainless steel cover to avoid the contact with hot water. The cover should have a hole that allows to visualize the water level and also to stuff the tank.
Draining water valve.
Centrifugal pump with speed control from computer, range: 0 - 3 l/min.

Two flow sensors, one for hot water and the other for cold water, range: 0.25 - 6.5 l/min.
Control valves for the cold and hot water.
Four ball valves that, depending on how manipulated, could give co¬current or counter-current flux in the exchanger.
Two ball valves to control and drain the hot water of the base unit. Pressure regulator to avoid the introduction of too much pressure in the exchangers, tared at 0.6 bar.
Four flexible tubes to connect with the different exchangers.
Dimensions: 1100 x 630 x 500 mm approx. (43.3 x 24.8 x 19.68 inches approx.). Weight: 50 kg approx. (110.2 pounds approx.).

With Concentric Tube Heat Exchanger:
Exchange length: L = 2 x 0.5 = 1 m.
Internal tube:
Internal diameter: Dint = 16 • 10-3 m.
External diameter: Dext = 18 • 10-3 m.
Thickness = 10-3 m.
Heat transfer internal area: Ah = 0.0503 m2.
Heat transfer external area: Ac = 0.0565 m2.